SHUTOFF GP
124 assemblies
SEBP1391 (46)
2W5216 AIR SHUT-OFF GROUP SERIAL NO. 27Z1 TO 27Z633 INCLUSIVE. PART OF 2W6115 AIR SHUT-OFF GROUP SHOWN ON PAGE 188
1 - 99999 2W5216 AIR SHUT-OFF GROUP SERIAL NO. 27Z634 TO 27Z637 INCLUSIVE PART OF 2W6115 AIR SHUT-OFF
1 - 99999 2W5216 AIR SHUT-OFF GROUP SERIAL NO. 27Z638-UP PART OF 2W6115 AIR SHUT-OFF
1 - 99999 2W6115 AIR SHUT-OFF GROUP-INTAKE SERIAL NO. 27Z1 TO 27Z644 INCLUSIVE 2W5216-PAGE 187B
1 - 99999 2W6115 AIR SHUT-OFF GROUP SERIAL NO. 27Z645-UP 2W5216-PAGE 187
1 - 99999 7W6957 SHUT-OFF SOLENOID GROUP SERIAL NO. 27Z647-UP. PART OF 7W8912 ELECTRICAL SHUT-OFF
1 - 99999 1W4862 REMOTE SHUT-OFF GROUP PART OF 8N6714 GOVERNOR & 8N4926 MECHANICAL SHUT-OFF ALSO AVAILABLE AS AN ATTACHMENT
1 - 99999 5N8200 REMOTE NORMAL SHUT-OFF CHART-TYPE 1 AN ATTACHMENT
1 - 99999 5N8200 REMOTE NORMAL SHUT-OFF CHART-TYPE 2 AN ATTACHMENT
1 - 99999 5N5880 EMERGENCY REMOTE SHUT-OFF GROUP PNEUMATIC/HYDRAULIC FUEL & AIR. AN ATTACHMENT
1 - 99999 1W1270 AIR SHUT-OFF GROUP-MECHANICAL PART OF 8N4926 MECHANICAL SHUT-OFF GROUP LISTED ON PAGE 308. REFER TO 5N5382 CHART LISTED ON PAGE 304 FOR USAGE. ALSO AVAILABLE AS AN ATTACHMENT
1 - 99999 8N4926 MECHANICAL SHUT-OFF GROUP-HIGH SPEED
1 - 99999 ELECTRICAL SHUT-OFF GROUP WOODWARD 3161-24/32 VOLT DC ENERGIZED TO RUN AN ATTACHMENT
1 - 99999 2W6120 ELECTRICAL SHUT-OFF ARRANGEMENT-24-32 VOLT-OVERSPEED NOT FOR USE WITH UG8L GOVERNOR AN ATTACHMENT
1 - 99999 7W6349 SHUT-OFF GP-ELECTRIC
1 - 99999 2W6121 ELECTRICAL SHUT-OFF GROUP-24-32 VOLT-OVERSPEED ONLY NOT FOR USE WITH UG8L GOVERNOR AN ATTACHMENT
1 - 99999 2W6122 ELECTRICAL SHUT-OFF ARRANGEMENT-24-32 VOLT NOT FOR USE WITH UG8L GOVERNOR AN ATTACHMENT
1 - 99999 2W6123 ELECTRICAL SHUT-OFF GROUP-24-32 VOLT NOT FOR USE WITH UG8L GOVERNOR AN ATTACHMENT
1 - 99999 7W8912 ELECTRICAL SHUT-OFF GROUP SERIAL NO. 27Z647-UP.
1 - 99999 1W4863 ELECTRICAL SHUT-OFF GROUP-24/32 VOLT DC FOR USE WITH 3161 GOVERNORS PART OF 8N6712 WOODWARD GOVERNOR & 7W8912 ELECTRICAL SHUT-OFF ALSO AN ATTACHMENT
1 - 99999 7W3610 ELECTRICAL SHUT-OFF GROUP-24 OR 32 VOLT AN ATTACHMENT
1 - 99999 7W8054 ELECTRICAL SHUT-OFF GROUP SERIAL NO. 27Z647-UP. PART OF 7W8912 ELECTRICAL SHUT-OFF
1 - 99999 5N1960 CONTROL SHUT-OFF GROUP-SIDE VIEW PART OF 8N4926 MECHANICAL SHUT-OFF GROUP LISTED ON PAGE 308. 5N1925 PUMP, 5N5990 & 5N2718 VALVE PARTS ARE SHOWN ON PAGES 324, 325 & 326. REFER TO 5N5382 CHART SHOWN ON PAGE 304 FOR USAGE. ALSO AVAILABLE AS AN ATTACHMENT
1 - 99999 5N1960 CONTROL SHUT-OFF GROUP-TOP VIEW PART OF 8N4926 MECHANICAL SHUT-OFF GROUP LISTED ON PAGE 308. 5N6443 VALVE PARTS ARE SHOWN ON PAGE 326. REFER TO 5N5382 CHART SHOWN ON PAGE 304 FOR USAGE. ALSO AVAILABLE AS AN ATTACHMENT
1 - 99999 5N5330 CONTROL SHUT-OFF GROUP-SIDE VIEW 5N1925 PUMP, 5N5990 & 5N2718 VALVE PARTS ARE SHOWN ON PAGES 324, 325 & 326 REFER TO 5N5382 CHART SHOWN ON PAGE 304 FOR USAGE. AN ATTACHMENT
1 - 99999 5N5330 CONTROL SHUT-OFF GROUP-TOP VIEW 5N6443 VALVE PARTS ARE SHOWN ON PAGE 326. REFER TO 5N5382 CHART SHOWN ON PAGE 304 FOR USAGE. AN ATTACHMENT
1 - 99999 5N5338 CONTROL SHUT-OFF GROUP-SIDE VIEW-PART 1 OF 2-TYPE 1 5N1925 PUMP-PAGE 324, 5N5990-PAGE 325, 5N7218-PAGE 326 PROVIDES OVERSPEED PROTECTION FOR ENGINES RATED AT 1500 RPM REFER TO 5N5382 CHART-PAGE 304. AN ATTACHMENT
1 - 99999 5N5338 CONTROL SHUT-OFF GROUP-TOP VIEW-PART 2 OF 2-TYPE 1 5N6443-PAGE 326 REFER TO 5N5382 CHART-PAGE 304 AN ATTACHMENT
1 - 99999 5N5338 CONTROL SHUT-OFF GROUP-SIDE VIEW-PART 1 OF 2-TYPE 2 5N1925-PAGE 324, 5N5990-PAGE 325, 5N2718-PAGE 326 PROVIDES OVERSPEED PROTECTION FOR ENGINES RATED AT 1500 RPM REFER TO 5N5382 CHART-PAGE 304. AN ATTACHMENT
1 - 99999 5N5338 CONTROL SHUT-OFF GROUP-TOP VIEW-PART 2 OF 2-TYPE 2 2W9635-PAGE 328 PROVIDES OVERSPEED PROTECTION FOR ENGINES RATED AT 1500 RPM REFER TO 5N5382 CHART-PAGE 304. AN ATTACHMENT
1 - 99999 5N5608 CONTROL SHUT-OFF GROUP-SIDE VIEW-PART 1 OF 2-TYPE 1 5N1925-PAGE 324,5N5990-PAGE 325, 5N2718-PAGE 326 REFER TO 5N5382 CHART-PAGE 308 AN ATTACHMENT
1 - 99999 5N5608 CONTROL SHUT-OFF GROUP-TOP VIEW-PART 2 OF 2-TYPE 1 5N6443-PAGE 326 REFER TI CGART 5B5382-PAGE 304 AN ATTACHMENT
1 - 99999 5N5608 CONTROL SHUT-OFF GROUP-SIDE VIEW-PART 1 OF 2-TYPE 2 5N1925-PAGE 324, 5N5990-PAGE 325, 5N2718-PAGE 326 PROVIDES OVERSPEED PROTECTION FOR ENGINES RATED AT 1800 RPM REFER TO 5N5382 CHART-PAGE 304. AN ATTACHMENT
1 - 99999 5N5608 CONTROL SHUT-OFF GROUP-TOP VIEW-PART 2 OF 2-TYPE 2 2W9635-PAGE 328 PROVIDES OVERSPEED PROTECTION FOR ENGINES RATED AT 1800 RPM REFER TO CHART-PAGE 304. AN ATTACHMENT
1 - 99999 2W4922 SHUT-OFF LINES GROUP-HYDRO-MECHANICAL FOR USE WITH 2W8947 WIRING AN ATTACHMENT
1 - 99999 2N6242 SHUT-OFF LINES GROUP FOR USE WITH R.H. HYDRO MECHANICAL GOVERNOR & 1W4862 REMOTE SHUT-OFF GROUP SHOWN ON PAGE 305. PART OF 8N4926 MECHANICAL SHUT-OFF GROUP LISTED ON PAGE 308. 2W6108 SHUT-OFF & 2W4925 VALVE PARTS ARE SHOWN ON PAGES 332 & 335F. ALSO AVAILABLE AS AN ATTACHMENT
1 - 99999 2W6108 AIR SHUT-OFF LINES GROUP-R.H. SERIAL NO. 27Z1 TO 27Z633 INCLUSIVE PART OF 2W6242 & 2W4922 SHUT-OFF LINES AN ATTACHMENT
1 - 99999 2W6108 AIR SHUT-OFF LINES GROUP-R.H. SERIAL NO. 27Z634-UP PART OF 2W6242, 2W6244, 2W4922 & 2W6243 SHUT-OFF LINES AN ATTACHMENT
1 - 99999 5N8295 SHUT-OFF LINES GROUP-MECHANICAL-R.H. GOVERNOR-PART 1 REFER TO 5N5382 CHART SHOWN ON PAGE 304 FOR USAGE. AN ATTACHMENT
1 - 99999 5N8295 SHUT-OFF LINES GROUP-MECHANICAL-R.H.-GOVERNOR-PART 2 REFER TO 5N5382 CHART SHOWN ON PAGE 304 FOR USAGE. AN ATTACHMENT
1 - 99999 5N9570 SHUT-OFF LINES GROUP-REPLACED BY 2W6243-PAGE 335D.01 2W4923-PAGE 335B, 2W4926-PAGE 335C REFER TO 5N5382 CHART-PAGE 304 AN ATTACHMENT
1 - 99999 2W4923 AIR SHUT-OFF LINES GROUP PART OF 5N9570 SHUT-OFF LINES GROUP SHOWN ON PAGE 335A. AN ATTACHMENT
1 - 99999 2W6244 SHUT-OFF LINES GROUP FOR USE WITH R.H. HYDRA-MECHANICAL GOVERNOR WITH OVERSPEED ONLY, & 1W4862 REMOTE SHUT-OFF GROUP SHOWN ON PAGE 305. 2W6108 & 2W4927 LINES PARTS ARE SHOWN ON PAGES 332 & 335E. AN ATTACHMENT
1 - 99999 2W6243 SHUT-OFF LINES GROUP-MECHANICAL 2W6108-PAGE 333, 2W4926-PAGE 335C FOR USE WITH ELECTRIC GOVERNOR AN ATTACHMENT
1 - 99999 5N5735 SHUT-OFF LINES GROUP-TYPE 1 REFER TO 5N5382 CHART-PAGE 304 AN ATTACHMENT
1 - 99999 5N5735 SHUT-OFF LINES GROUP-TYPE 2 REFER TO 5N5382 CHART-PAGE 304 AN ATTACHMENT
1 - 99999 SEBP1639 (46)
2W-4923 LINES GP-AIR SHUTOFF S/N 71Z243-353 PART OF 5N-8295, 5N-9570 LINES GP-SHUTOFF AN ATTACHMENT
1 - 99999 113-1324 SHUTOFF GP-AIR S/N 27Z650-771 AN ATTACHMENT
1 - 99999 113-1324 SHUTOFF GP-AIR S/N 27Z772-791 AN ATTACHMENT
1 - 99999 135-0180 SHUTOFF GP-AIR S/N 27Z650-791 PART OF 113-1324 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 144-8275 SHUTOFF GP-AIR PART OF 357-7134, 357-7135, 357-7136 LINES GP-AIR, 4W-3048, 7C-5032 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 2W-5216 SHUTOFF GP-AIR PART OF 2W-6115, 4W-3048 SHUTOFF GP-AIR ALSO AN ATTACHMENT
1 - 99999 2W-5216 SHUTOFF GP-AIR PART OF 4W-3048 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 2W-6115 SHUTOFF GP-AIR S/N 27Z650-659; 71Z243-252 INTAKE
1 - 99999 4W-3048 SHUTOFF GP-AIR -INTAKE PART OF 7C-5032 SHUTOFF GP-AIR Type 1 FOR USE WITH HYDROMECHANICAL SHUTOFF AN ATTACHMENT
1 - 99999 4W-3048 SHUTOFF GP-AIR -INTAKE PART OF 7C-5032 SHUTOFF GP-AIR Type 2 FOR USE WITH HYDROMECHANICAL SHUTOFF AN ATTACHMENT
1 - 99999 7C-5032 SHUTOFF GP-AIR -INTAKE 24-VOLT TO 32-VOLT DC Type 1 AN ATTACHMENT
1 - 99999 7C-5032 SHUTOFF GP-AIR -INTAKE 24-VOLT TO 32-VOLT DC Type 2 AN ATTACHMENT
1 - 99999 7C-0240 CONTROL GP-AUTO START/STOP 32 VOLT DC FOR USE WITH JUNCTION BOX AN ATTACHMENT
1 - 99999 2W-6108 LINES GP-SHUTOFF -RH PART OF 7W-7324, 7W-7325 SHUTOFF GP-ELECTRICAL, 4W-6981, 4W-6982 SHUTOFF GP-HYDROMECHANICAL AN ATTACHMENT
1 - 99999 4P-5021 LINES GP-SHUTOFF PART OF 7W-7324, 7W-7325 SHUTOFF GP-ELECTRICAL AN ATTACHMENT
1 - 99999 4P-7245 LINES GP-SHUTOFF S/N 27Z650-791 AN ATTACHMENT
1 - 99999 4W-6886 LINES GP-SHUTOFF -EXTENSION PART OF 7W-7324, 7W-7325 SHUTOFF GP-ELECTRICAL, 4W-6981, 4W-6982 SHUTOFF GP-HYDROMECHANICAL AN ATTACHMENT
1 - 99999 5N-5735 LINES GP-SHUTOFF -LH MECHANICAL-GOVERNOR FOR USAGE REFER TO CHART 5N-5382, 7W-7326 AN ATTACHMENT
1 - 99999 5N-8295 LINES GP-SHUTOFF -RH S/N 71Z243-353 MECHANICAL-GOVERNOR FOR USE WITH HYDRA-MECHANICAL SHUT-OFF & UG8L GOVERNOR FOR USAGE REFER TO CHART 5N-5382 AN ATTACHMENT
1 - 99999 5N-9570 LINES GP-SHUTOFF S/N 71Z243-353 MECHANICAL--ELEC GOV. LISTED ON CHART 5N5382 FOR USAGE REFER TO CHART 5N-5382 CHART-ALARM SYSTEM AN ATTACHMENT
1 - 99999 5N-5328 SHUTOFF GP-CONTROL S/N 71Z243-353 FOR USAGE REFER TO CHART 5N-5382, 7W-7326 AN ATTACHMENT
1 - 99999 5N-5330 SHUTOFF GP-CONTROL S/N 27Z650-791 FOR USAGE REFER TO CHART 7W-7326 AN ATTACHMENT
1 - 99999 5N-6050 SHUTOFF GP-CONTROL S/N 71Z243-353 PROVIDES OVERSPEED PROTECTION FOR ENGINES RATED AT 1000 RPM FOR USAGE REFER TO CHART 5N-5382 AN ATTACHMENT
1 - 99999 5N-6051 SHUTOFF GP-CONTROL S/N 71Z243-353 PROVIDES OVERSPEED PROTECTION FOR ENGINES RATED AT 1200 RPM PART OF 7W-7324 SHUTOFF GP-ELECTRICAL FOR USAGE REFER TO CHART 5N-5382 AN ATTACHMENT
1 - 99999 166-4363 SHUTOFF GP-ELECTRICAL CANNOT BE USED WITH HYDROMECHANICAL SHUT-OFF AN ATTACHMENT
1 - 99999 1W-4863 SHUTOFF GP-ELECTRICAL S/N 27Z650-655; 71Z243-353 24-VOLT, 32-VOLT. ENERGIZED TO RUN PART OF 7W-8912 SHUTOFF GP-ELECTRICAL ALSO AN ATTACHMENT
1 - 99999 7C-1892 SHUTOFF GP-ELECTRICAL 64 VOLT. LOCOMOTIVE AN ATTACHMENT
1 - 99999 7C-5237 SHUTOFF GP-ELECTRICAL S/N 27Z660-791; 71Z253-353 ENERGIZED TO SHUT-OFF-OVERSPEED, OIL PRESSURE, WATER TEMPERATURE PART OF 7C-5274 SHUTOFF GP-ELECTRICAL
1 - 99999 7C-5274 SHUTOFF GP-ELECTRICAL S/N 27Z660-791; 71Z253-353 ENERGIZED TO SHUT-OFF-OVERSPEED,OIL PRESSURE,WATER TEMPERATURE
1 - 99999 7C-5275 SHUTOFF GP-ELECTRICAL S/N 27Z660-791; 71Z253-353 ENERGIZED TO SHUT-OFF-OVERSPEED AN ATTACHMENT
1 - 99999 7W-3555 SHUTOFF GP-ELECTRICAL S/N 27Z656-791; 71Z251-353 24-VOLT, 32-VOLT. ENERGIZED TO SHUTDOWN PART OF 7C-5274, 7W-8912 SHUTOFF GP-ELECTRICAL ALSO AN ATTACHMENT
1 - 99999 7W-3610 SHUTOFF GP-ELECTRICAL 24-VOLT, 32-VOLT. ENERGIZED TO RUN AN ATTACHMENT
1 - 99999 7W-3955 SHUTOFF GP-ELECTRICAL 64/76 VOLT DC. ENERGIZED TO RUN FOR USE WITH 3161 GOVERNOR WITH 115 VOLT AC SYSTEMS AN ATTACHMENT
1 - 99999 7W-6349 SHUTOFF GP-ELECTRICAL S/N 27Z650-791 PART OF 7W-7651 CONVERSION AR AN ATTACHMENT
1 - 99999 7W-7324 SHUTOFF GP-ELECTRICAL S/N 71Z243-353 HYDRO-MECHANICAL-LOW SPEED FOR USAGE REFER TO CHART 7W-7326 AN ATTACHMENT
1 - 99999 7W-7325 SHUTOFF GP-ELECTRICAL S/N 27Z650-791 HYDROMECHANICAL-HIGH SPEED FOR USAGE REFER TO CHART 7W-7326 AN ATTACHMENT
1 - 99999 7W-8053 SHUTOFF GP-ELECTRICAL S/N 27Z650-659; 71Z243-252 ENERGIZED TO SHUT-OFF, OVERSPEED CANNOT BE USED WITH HYDROMECHANICAL SHUT-OFF SYSTEM AN ATTACHMENT
1 - 99999 7W-8053 SHUTOFF GP-ELECTRICAL S/N 27Z660-791; 71Z253-353 ENERGIZED TO SHUT-OFF, OVERSPEED CANNOT BE USED WITH HYDROMECHANICAL SHUT-OFF SYSTEM AN ATTACHMENT
1 - 99999 7W-8054 SHUTOFF GP-ELECTRICAL S/N 27Z650-659; 71Z243-252 ENERGIZED TO SHUTOFF-OVERSPEED, OIL PRESSURE, WATER TEMPERATURE PART OF 7W-8912 SHUTOFF GP-ELECTRICAL ALSO AN ATTACHMENT
1 - 99999 7W-8912 SHUTOFF GP-ELECTRICAL S/N 27Z650-659; 71Z243-252
1 - 99999 113-1325 SOLENOID GP-SHUTOFF -AIR S/N 27Z650-771 24-VOLT TO 32-VOLT DC PART OF 113-1324 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 141-6747 SOLENOID GP-SHUTOFF -AIR S/N 27Z772-791 24-VOLT TO 32-VOLT DC PART OF 113-1324 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 7W-6957 SOLENOID GP-SHUTOFF -AIR S/N 27Z650-659; 71Z243-252 24-VOLT TO 32-VOLT DC PART OF 7C-5032 SHUTOFF GP-AIR, 7W-8912 SHUTOFF GP-ELECTRICAL ALSO AN ATTACHMENT
1 - 99999 7W-6957 SOLENOID GP-SHUTOFF -AIR 24-VOLT TO 32-VOLT DC PART OF 357-7134, 357-7135 LINES GP-AIR, 7C-5032 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 7W-8640 SOLENOID GP-SHUTOFF -AIR 64 VOLT DC AN ATTACHMENT
1 - 99999 5N-8200 CHART-REMOTE SHUTOFF AN ATTACHMENT
1 - 99999 SEBP2967 (32)
113-1324 SHUTOFF GP-AIR S/N 27Z792-842 AN ATTACHMENT
1 - 99999 113-1324 SHUTOFF GP-AIR S/N 27Z843-UP AN ATTACHMENT
1 - 99999 135-0180 SHUTOFF GP-AIR S/N 27Z792-842 PART OF 113-1324 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 144-8275 SHUTOFF GP-AIR PART OF 357-7134, 357-7135 LINES GP-AIR, 4W-3048, 7C-5032 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 359-4912 SHUTOFF GP-AIR S/N 27Z843-UP PART OF 113-1324 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 4W-3048 SHUTOFF GP-AIR -INTAKE PART OF 7C-5032 SHUTOFF GP-AIR FOR USE WITH HYDROMECHANICAL SHUTOFF AN ATTACHMENT
1 - 99999 7C-5032 SHUTOFF GP-AIR -INTAKE 24-VOLT TO 32-VOLT DC Type 1 AN ATTACHMENT
1 - 99999 7C-5032 SHUTOFF GP-AIR -INTAKE 24-VOLT TO 32-VOLT DC Type 2 AN ATTACHMENT
1 - 99999 2W-6108 LINES GP-SHUTOFF -RH PART OF 7W-7325 SHUTOFF GP-ELECTRICAL, 4W-6982 SHUTOFF GP-HYDROMECHANICAL AN ATTACHMENT
1 - 99999 4P-5021 LINES GP-SHUTOFF PART OF 7W-7325 SHUTOFF GP-ELECTRICAL AN ATTACHMENT
1 - 99999 4P-7245 LINES GP-SHUTOFF AN ATTACHMENT
1 - 99999 4W-6886 LINES GP-SHUTOFF -EXTENSION PART OF 4W-6982 SHUTOFF GP-HYDROMECHANICAL AN ATTACHMENT
1 - 99999 5N-5735 LINES GP-SHUTOFF -LH MECHANICAL-GOVERNOR FOR USAGE REFER TO CHART 5N-5382, 7W-7326 AN ATTACHMENT
1 - 99999 172-0256 SHUTOFF GP-CONTROL Type 1 AN ATTACHMENT
1 - 99999 172-0256 SHUTOFF GP-CONTROL Type 2 AN ATTACHMENT
1 - 99999 5N-5330 SHUTOFF GP-CONTROL FOR USAGE REFER TO CHART 7W-7326 AN ATTACHMENT
1 - 99999 166-4363 SHUTOFF GP-ELECTRICAL CANNOT BE USED WITH HYDROMECHANICAL SHUT-OFF AN ATTACHMENT
1 - 99999 7C-1892 SHUTOFF GP-ELECTRICAL 64 VOLT. LOCOMOTIVE AN ATTACHMENT
1 - 99999 7C-5237 SHUTOFF GP-ELECTRICAL ENERGIZED TO SHUT-OFF-OVERSPEED, OIL PRESSURE, WATER TEMPERATURE PART OF 7C-5274 SHUTOFF GP-ELECTRICAL
1 - 99999 7C-5274 SHUTOFF GP-ELECTRICAL ENERGIZED TO SHUT-OFF-OVERSPEED,OIL PRESSURE,WATER TEMPERATURE
1 - 99999 7C-5275 SHUTOFF GP-ELECTRICAL ENERGIZED TO SHUT-OFF-OVERSPEED AN ATTACHMENT
1 - 99999 7W-3555 SHUTOFF GP-ELECTRICAL 24-VOLT, 32-VOLT. ENERGIZED TO SHUTDOWN PART OF 7C-5274 SHUTOFF GP-ELECTRICAL ALSO AN ATTACHMENT
1 - 99999 7W-3610 SHUTOFF GP-ELECTRICAL 24-VOLT, 32-VOLT. ENERGIZED TO RUN AN ATTACHMENT
1 - 99999 7W-3955 SHUTOFF GP-ELECTRICAL 64/76 VOLT DC. ENERGIZED TO RUN FOR USE WITH 3161 GOVERNOR WITH 115 VOLT AC SYSTEMS AN ATTACHMENT
1 - 99999 7W-6349 SHUTOFF GP-ELECTRICAL AN ATTACHMENT
1 - 99999 7W-7325 SHUTOFF GP-ELECTRICAL HYDROMECHANICAL-HIGH SPEED FOR USAGE REFER TO CHART 7W-7326 AN ATTACHMENT
1 - 99999 7W-8053 SHUTOFF GP-ELECTRICAL ENERGIZED TO SHUT-OFF, OVERSPEED CANNOT BE USED WITH HYDROMECHANICAL SHUT-OFF SYSTEM AN ATTACHMENT
1 - 99999 7W-8054 SHUTOFF GP-ELECTRICAL ENERGIZED TO SHUTOFF-OVERSPEED, OIL PRESSURE, WATER TEMPERATURE AN ATTACHMENT
1 - 99999 141-6747 SOLENOID GP-SHUTOFF -AIR 24-VOLT TO 32-VOLT DC PART OF 113-1324 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 7W-6957 SOLENOID GP-SHUTOFF -AIR 24-VOLT TO 32-VOLT DC PART OF 357-7134, 357-7135 LINES GP-AIR, 7C-5032 SHUTOFF GP-AIR AN ATTACHMENT
1 - 99999 7W-8640 SOLENOID GP-SHUTOFF -AIR 64 VOLT DC AN ATTACHMENT
1 - 99999 5N-8200 CHART-REMOTE SHUTOFF AN ATTACHMENT
1 - 99999