Families
▶ARTICULATED DUMP TRUCK
▶ASPHALT PAVER
▶BACKHOE LOADER
▶CHALLENGER
▶COLD PLANER
▶COMBINE
▶CONTROL, GUIDANCE, MONITORING, AND TECHNOLOGY PRODUCTS
▶DRILL
▶EARTHMOVING COMPACTOR
▶ENGINE - GENERATOR SET
▶ENGINE - INDUSTRIAL
▶ENGINE - MACHINE
▶ENGINE - TRUCK
▶ENGINEER SUPPORT TRACTOR
▶EXCAVATOR
▶EXPANDED MINING PRODUCTS
▶FOREST PRODUCTS
▶GENERATOR
▶INTEGRATED TOOLCARRIER
▶LOAD, HAUL, DUMP
▶MARINE PRODUCTS
▶MATERIAL HANDLER
▶MINI HYDRAULIC EXCAVATOR
▶MOTOR GRADER
▶OEM SOLUTIONS
▶OFF-HIGHWAY TRUCK
▶ON HIGHWAY TRUCK
▶PAVING COMPACTOR
▶PETROLEUM PRODUCTS
▶PIPELAYER
▶POWER SYSTEMS
▶RENEWABLE ENERGY
▶RETROFIT AFTERTREATMENT
▶ROAD RECLAIMER
▶SKID STEER LOADER
▶TECHNOLOGY
▶TELEHANDLER
▶TILLAGE
▶TRACK-TYPE LOADER
▶TRACK-TYPE SKIDDER
▶TRACK-TYPE TRACTOR
▶UNDERGROUND ARTICULATED TRUCK
▶UTILITY VEHICLE
▶WHEEL DOZER
▶WHEEL TRACTOR-SCRAPER
▶WHEEL-TYPE LOADER
▶WHEEL-TYPE SKIDDER
▶WHEELED EXCAVATOR
▶WORK TOOL

1639385

BONNET-OUTLET

← Back
5Models
50Assemblies
30Co-occurring
Part Information ▼
BrandCaterpillarWeight22.19 lb (10.07 kg)
▼Compatible Models (5)
▼Found in Assemblies (50)
AssemblyModelRef#QtyNote
159-1597 LINES GP-WATERPROVIDES ENGINE OIL COOLER, STANDARD WATER OUTLET LOCATION, AND 190 DEGREE STAT DOUBLE THERMOSTAT HOUSING · Type 13406E10
159-1597 LINES GP-WATERPROVIDES ENGINE OIL COOLER, STANDARD WATER OUTLET LOCATION, AND 190 DEGREE STAT DOUBLE THERMOSTAT HOUSING · Type 23406E9
159-9595 LINES GP-WATERFOR USE WITH ADEM III CONTROL · ALSO AN ATTACHMENT3406E17
159-9596 LINES GP-WATERFOR USE WITH ADEM III CONTROL, AUTOMATIC TRANSMISSION · ALSO AN ATTACHMENT3406E18
162-5405 LINES GP-WATERS/N 2WS1-42798 · CANNOT BE USED WITH BRAKESAVER3406E18
165-8078 LINES GP-WATERFOR USE WITH RH OIL GAGE GP · CANNOT BE USED WITH BRAKESAVER3406E16
167-6823 LINES GP-WATERS/N 2WS693-427983406E17
137-9750 LINES GP-WATERSTANDARD WATER OUTLET, 190 DEGREE DOUBLE THERMOSTAT HOUSING · CANNOT BE USED WITH BRAKESAVER3406E17
142-8119 LINES GP-WATER190 DEGREE DOUBLE THERMOSTAT HOUSING, FOR USE WITH AUTOMATIC TRANSMISSION REQUIRING WATER FLOW TO THE TRANSMISSION WHILE ENGINE IS ON THERMOSTAT BYPASS MODE · AN ATTACHMENT3406E8
160-1735 LINES GP-WATERS/N 5DS751-1087 · 190 DEGREE DOUBLE THERMOSTAT HOUSING, PROVIDES HOUSING WITH AIR COMPRESSOR WATER INLET3406E17
166-1748 LINES GP-WATERS/N 5DS786-1087 · 190 DEG STAT DOUBLE THERMOSTAT HSG, RH SIDE FRONT WATER INLET3406E20
137-9750 LINES GP-WATERSTANDARD WATER OUTLET, 190 DEGREE DOUBLE THERMOSTAT HOUSING · CANNOT BE USED WITH BRAKESAVER3406E17
142-8119 LINES GP-WATER190 DEGREE DOUBLE THERMOSTAT HOUSING, FOR USE WITH AUTOMATIC TRANSMISSION REQUIRING WATER FLOW TO THE TRANSMISSION WHILE ENGINE IS ON THERMOSTAT BYPASS MODE · ALSO AN ATTACHMENT3406E8
160-1735 LINES GP-WATER190 DEGREE DOUBLE THERMOSTAT HOUSING, PROVIDES HOUSING WITH AIR COMPRESSOR WATER INLET · FOR USE WITH RH OIL GAUGE3406E17
166-1748 LINES GP-WATERS/N 1LW21433-UP · 190 DEG STAT DOUBLE THERMOSTAT HSG, RH SIDE FRONT WATER INLET3406E20
159-1597 LINES GP-WATERPROVIDES ENGINE OIL COOLER, STANDARD WATER OUTLET LOCATION, AND 190 DEGREE STAT DOUBLE THERMOSTAT HOUSING · Type 1345610
159-1597 LINES GP-WATERPROVIDES ENGINE OIL COOLER, STANDARD WATER OUTLET LOCATION, AND 190 DEGREE STAT DOUBLE THERMOSTAT HOUSING · Type 234569
159-9595 LINES GP-WATERFOR USE WITH ADEM III CONTROL · ALSO AN ATTACHMENT3406E17
159-9596 LINES GP-WATERFOR USE WITH ADEM III CONTROL, AUTOMATIC TRANSMISSION · AN ATTACHMENT3406E18
162-5405 LINES GP-WATERS/N 1MM1-1487 · CANNOT BE USED WITH BRAKESAVER3406E18
165-8078 LINES GP-WATERFOR USE WITH RH OIL GAGE GP · CANNOT BE USED WITH BRAKESAVER3406E16
167-6823 LINES GP-WATERS/N 1MM154-14873406E17
173-5992 COOLING ARS/N 6NZ1-99999; 9NZ1-7864 · PROVIDES SIDE WATER INLET WATER LOCATIONC-1519
173-5992 COOLING ARS/N 9NZ7865-UP · PROVIDES SIDE WATER INLET WATER LOCATIONC-1519
160-0469 LINES GP-WATERCANNOT BE USED WITH BRAKESAVER · ALSO AN ATTACHMENTC-1516
160-0470 LINES GP-WATERS/N 6NZ1-99999; 9NZ1-7864 · FOR USE WITH AUTO TRANSMISSIONC-1518
160-0470 LINES GP-WATERS/N 9NZ1-UP · FOR USE WITH AUTO TRANSMISSIONC-1518
167-6818 LINES GP-WATERS/N 6NZ1-99999; 9NZ1-7864 · FOR USE WITH RIGHT SIDE OIL GAUGE GROUPC-1516
167-6818 LINES GP-WATERS/N 9NZ7865-UP · FOR USE WITH RIGHT SIDE OIL GAUGE GROUPC-1516
195-7415 LINES GP-WATERS/N 6NZ1-99999; 9NZ1-7864 · PROVIDES ENGINE OIL COOLER, STANDARD WATER OUTLET, AND 190 DEGREE DUAL STAT REGULATOR HOUSING WITH STUD IN REAR TOP LOCATIONC-1516
195-7415 LINES GP-WATERS/N 9NZ7865-UP · PROVIDES ENGINE OIL COOLER, STANDARD WATER OUTLET, AND 190 DEGREE DUAL STAT REGULATOR HOUSING WITH STUD IN REAR TOP LOCATIONC-1516
223-9811 LINES GP-WATERFOR USE WITH 154-6691, 162-8780, IF NO RIGHT FRONT GUIDE, OEM CONNECTION FOR AUTO TRANSMISSION · CANNOT BE USED WITH BRAKESAVER AND COOLANT CONDITIONER GROUPSC-1516
225-1529 LINES GP-WATERRIGHT HAND SIDE, FORWARD ANGLE, FRONT WATER INLET AND DUAL 190 DEGREE THERMOSTATS, REQUIRES OEM CONNECTIONS FOR AUTOMATIC TRANSMISSION · FOR USE WITH 154-6691, 162-8780C-1516
173-5992 COOLING ARS/N 7CZ1-5682 · PROVIDES SIDE WATER INLET WATER LOCATIONC-1619
173-5992 COOLING ARS/N 7CZ5683-UP · PROVIDES SIDE WATER INLET WATER LOCATIONC-1619
160-0469 LINES GP-WATERCANNOT BE USED WITH BRAKESAVER · ALSO AN ATTACHMENTC-1616
160-0470 LINES GP-WATERS/N 7CZ1-5682 · FOR USE WITH AUTO TRANSMISSIONC-1618
160-0470 LINES GP-WATERS/N 7CZ5683-UP · FOR USE WITH AUTO TRANSMISSIONC-1618
167-6818 LINES GP-WATERS/N 7CZ1-5682 · FOR USE WITH RIGHT SIDE OIL GAUGE GROUPC-1616
167-6818 LINES GP-WATERS/N 7CZ5683-UP · FOR USE WITH RIGHT SIDE OIL GAUGE GROUPC-1616
195-7415 LINES GP-WATERS/N 7CZ1-5682 · PROVIDES ENGINE OIL COOLER, STANDARD WATER OUTLET, AND 190 DEGREE DUAL STAT REGULATOR HOUSING WITH STUD IN REAR TOP LOCATIONC-1616
195-7415 LINES GP-WATERS/N 7CZ5683-UP · PROVIDES ENGINE OIL COOLER, STANDARD WATER OUTLET, AND 190 DEGREE DUAL STAT REGULATOR HOUSING WITH STUD IN REAR TOP LOCATIONC-1616
223-9811 LINES GP-WATERFOR USE WITH 154-6691, 162-8780, IF NO RIGHT FRONT GUIDE, OEM CONNECTION FOR AUTO TRANSMISSION · CANNOT BE USED WITH BRAKESAVER AND COOLANT CONDITIONER GROUPSC-1616
225-1529 LINES GP-WATERRIGHT HAND SIDE, FORWARD ANGLE, FRONT WATER INLET AND DUAL 190 DEGREE THERMOSTATS, REQUIRES OEM CONNECTIONS FOR AUTOMATIC TRANSMISSION · FOR USE WITH 154-6691, 162-8780C-1616
170-6696 LINES GP-WATERS/N 9BZ1-UP · AN ATTACHMENT345610
159-1597 LINES GP-WATERS/N BGA1-UP · PROVIDES ENGINE OIL COOLER, STANDARD WATER OUTLET LOCATION, AND 190 DEGREE STAT DOUBLE THERMOSTAT HOUSING34569
187-8925 LINES GP-WATERFOR USE WITH FORWARD POSITION WATER PUMP · AN ATTACHMENTC-168
187-8925 LINES GP-WATERFOR USE WITH FORWARD POSITION WATER PUMP · AN ATTACHMENTC-158
203-8352 LINES GP-WATERType 1 · FOR USE WITH WATER COOLED CORESC-158
203-8352 LINES GP-WATERType 2 · FOR USE WITH WATER COOLED CORESC-158