Families
▶ARTICULATED DUMP TRUCK
▶ASPHALT PAVER
▶BACKHOE LOADER
▶CHALLENGER
▶COLD PLANER
▶COMBINE
▶CONTROL, GUIDANCE, MONITORING, AND TECHNOLOGY PRODUCTS
▶DRILL
▶EARTHMOVING COMPACTOR
▶ENGINE - GENERATOR SET
▶ENGINE - INDUSTRIAL
▶ENGINE - MACHINE
▶ENGINE - TRUCK
▶ENGINEER SUPPORT TRACTOR
▶EXCAVATOR
▶EXPANDED MINING PRODUCTS
▶FOREST PRODUCTS
▶GENERATOR
▶INTEGRATED TOOLCARRIER
▶LOAD, HAUL, DUMP
▶MARINE PRODUCTS
▶MATERIAL HANDLER
▶MINI HYDRAULIC EXCAVATOR
▶MOTOR GRADER
▶OEM SOLUTIONS
▶OFF-HIGHWAY TRUCK
▶ON HIGHWAY TRUCK
▶PAVING COMPACTOR
▶PETROLEUM PRODUCTS
▶PIPELAYER
▶POWER SYSTEMS
▶RENEWABLE ENERGY
▶RETROFIT AFTERTREATMENT
▶ROAD RECLAIMER
▶SKID STEER LOADER
▶TECHNOLOGY
▶TELEHANDLER
▶TILLAGE
▶TRACK-TYPE LOADER
▶TRACK-TYPE SKIDDER
▶TRACK-TYPE TRACTOR
▶UNDERGROUND ARTICULATED TRUCK
▶UTILITY VEHICLE
▶WHEEL DOZER
▶WHEEL TRACTOR-SCRAPER
▶WHEEL-TYPE LOADER
▶WHEEL-TYPE SKIDDER
▶WHEELED EXCAVATOR
▶WORK TOOL

2396807

CLAMP AS

← Back
4Models
50Assemblies
30Co-occurring
▼Compatible Models (4)
▼Found in Assemblies (50)
AssemblyModelRef#QtyNote
233-2529 LINES GP-AIR -LOW INTERSTAGEREQUIRES EXHAUST MANIFOLD GROUP AND PROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOS · FOR USE WITH LOW MOUNT TURBO LOCATIONC155×4
233-2531 LINES GP-AIR -MID INTERSTAGEPROVIDES INTERSTAGE PIPING BETWEEN SERIES TURBOCHARGERS, REQUIRES: MID MOUNT EXHAUST MANIFOLD · FOR USE WITH MID MOUNT TURBOCHARGERC154×4
233-2533 LINES GP-AIR -HIGH INTERSTAGEPROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOS, REQUIRES EXHAUST MANIFOLD GROUP · FOR USE WITH HIGH MOUNT TURBO LOCATIONC154×4
224-5396 LINES GP-AIR -LOW MOUNTPROVIDES INNER STAGE DUCTING FOR LOW-MOUNT TURBOCHARGER · ALSO AN ATTACHMENTC114×2
224-5397 LINES GP-AIR -HIGH MOUNTPROVIDES INNER STAGE DUCTING FOR THE HIGH-MOUNT TURBOCHARGER · ALSO AN ATTACHMENTC114×2
224-5443 LINES GP-AIR -MID MOUNTPROVIDES INNER STAGE DUCTING FOR MID-MOUNT TURBOCHARGER · ALSO AN ATTACHMENTC114×2
243-4520 LINES GP-AIR -TURBOCHARGERINTER STAGE DUCTING FOR THE LOW CAB FORWARD MOUNT, SERIES TURBO · ALSO AN ATTACHMENTC115×2
224-5396 LINES GP-AIR -LOW MOUNTPROVIDES INNER STAGE DUCTING FOR LOW-MOUNT TURBOCHARGER · ALSO AN ATTACHMENTC134×2
224-5397 LINES GP-AIR -HIGH MOUNTPROVIDES INNER STAGE DUCTING FOR THE HIGH-MOUNT TURBOCHARGER · ALSO AN ATTACHMENTC134×2
224-5443 LINES GP-AIR -MID MOUNTPROVIDES INNER STAGE DUCTING FOR MID-MOUNT TURBOCHARGER · ALSO AN ATTACHMENTC134×2
243-4520 LINES GP-AIR -TURBOCHARGERINTER STAGE DUCTING FOR THE LOW CAB FORWARD MOUNT, SERIES TURBO · ALSO AN ATTACHMENTC135×2
233-2529 LINES GP-AIR -LOW INTERSTAGES/N MXS333-99999; NXS1-31301; NXS31330-UP · REQUIRES EXHAUST MANIFOLD GROUP AND PROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOSC155×4
233-2531 LINES GP-AIR -MID INTERSTAGES/N MXS333-99999; NXS1-UP · PROVIDES INTERSTAGE PIPING BETWEEN SERIES TURBOCHARGERS, REQUIRES: MID MOUNT EXHAUST MANIFOLDC154×4
233-2533 LINES GP-AIR -HIGH INTERSTAGEPROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOS, REQUIRES EXHAUST MANIFOLD GROUP · FOR USE WITH HIGH MOUNT TURBO LOCATIONC154×4
291-9708 PRECOOLER GPPROVIDES A PRECOOLER GP FOR CHASSIS WHERE THE AIR TO AIR AFTERCOOLER CANNOT ACCEPT INLET TEMPS HIGHER THAN 260 DEG C. · ALSO AN ATTACHMENTC97×2
260-1458 LINES GP-CLEAN GAS INDUCTIONALSO AN ATTACHMENTC132
272-5363 LINES GP-CLEAN GAS INDUCTIONPROVIDES CONNECTION POINT ABOVE THE FLYWHEEL HOUSING · ALSO AN ATTACHMENTC132
280-6954 LINES GP-CLEAN GAS INDUCTIONPROVIDES AN OVER THE FLYWHEEL HOUSING OEM CGI CONNECTING POINT · FOR USE WITH 273-3530, HORIZONTAL VENTURIC133
280-6956 LINES GP-CLEAN GAS INDUCTIONPROVIDES AN OEM CGI CONNECTING POINT ORIENTED 90-DEGREES DOWN FROM THE CGI COOLER INLET · FOR USE WITH VERTICAL VENTURIC133
283-0253 LINES GP-CLEAN GAS INDUCTIONPROVIDES AN OEM CONNECTION POINT THAT IS AT A SLIGHT ANGLE BACK FROM VERTICAL · FOR USE WITH ANGLED VMAF WITH CLAM SHELL DESIGNC133
283-0254 LINES GP-CLEAN GAS INDUCTION -PRECOOLER INLETPROVIDES A LINES GP-AIR FOR ENGINES BUILT WITH A HORIZONTAL VENTURI. PROVIDES AN OVER THE FLYWHEEL HOUSING OEM CGI, CONNECTING POINT. · FOR USE WITH 290-1369C133
285-0206 LINES GP-CLEAN GAS INDUCTIONPROVIDES A LINES-GP AIR FOR THE VERTICAL VENTURI CGI · ALSO AN ATTACHMENTC133
267-6668 LINES GP-TURBOCHARGER AIRPART OF 341-1173 ENGINE AR-COMPLETE · FOR USE WITH LOW MOUNT TURBO CONFIGURATIONSC131×4
267-6669 LINES GP-TURBOCHARGER AIRFOR USE WITH MID-MOUNT TURBO CONFIGURATIONS · ALSO AN ATTACHMENTC131×4
267-6670 LINES GP-TURBOCHARGER AIRFOR USE WITH HIGH MOUNT TURBO CONFIGURATIONS · ALSO AN ATTACHMENTC131×4
292-1960 LINES GP-TURBOCHARGER AIRPROVIDES INTERSTAGE AIR DUCTING BETWEEN SERIES TURBOCHARGERS · FOR USE WITH LOW CAB FORWARD MANIFOLD GP-EXHC133×2
292-1960 LINES GP-TURBOCHARGER AIRS/N LEE13955-UP · PROVIDES INTERSTAGE AIR DUCTING BETWEEN SERIES TURBOCHARGERSC133×2
287-6940 LINES GP-WATER -PRECOOLER INLETS/N SDP518-5749 · PART OF 272-9889 PRECOOLER GPC153×2
287-6940 LINES GP-WATER -PRECOOLER INLETS/N SDP5750-6048 · PART OF 272-9889 PRECOOLER GPC153×2
287-6940 LINES GP-WATER -PRECOOLER INLETS/N SDP6049-UP · PART OF 272-9889 PRECOOLER GPC153×2
287-6942 LINES GP-WATER -PRECOOLER INLETS/N SDP1191-UP · MID MOUNTC153×2
288-0772 LINES GP-WATER -PRECOOLER INLETS/N SDP1191-UP · HIGH MOUNTC153×2
264-7847 LINES GP-AIRS/N SDP1-399 · PROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOCHARGERSC151×2
264-7847 LINES GP-AIRS/N SDP400-499 · PROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOCHARGERSC151×2
264-7847 LINES GP-AIRS/N SDP500-UP · PROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOCHARGERSC151×2
266-9787 LINES GP-AIRS/N SDP1-399 · PROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOCHARGERS FOR THE LOW MOUNT ENHANCED AIR SYSTEM TURBO CONFIGURATIONC151×2
266-9787 LINES GP-AIRS/N SDP400-499 · PROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOCHARGERS FOR THE LOW MOUNT ENHANCED AIR SYSTEM TURBO CONFIGURATIONC152×2
266-9787 LINES GP-AIRS/N SDP500-UP · PROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOCHARGERS FOR THE LOW MOUNT ENHANCED AIR SYSTEM TURBO CONFIGURATIONC151×2
266-9788 LINES GP-AIRS/N SDP1-399 · PROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOCHARGERS FOR THE HIGH MOUNT ENHANCED AIR SYSTEM TURBO CONFIGURATIONC151×2
266-9788 LINES GP-AIRS/N SDP400-499 · PROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOCHARGERS FOR THE HIGH MOUNT ENHANCED AIR SYSTEM TURBO CONFIGURATIONC152×2
266-9788 LINES GP-AIRPROVIDES INTERSTAGE PIPING BETWEEN THE SERIES TURBOCHARGERS FOR THE HIGH MOUNT ENHANCED AIR SYSTEM TURBO CONFIGURATION · FOR USE WITH EXHAUST MANIFOLD GROUPC151×2
273-0112 LINES GP-AIR -CLEAN GAS INDUCTION INLET90 DEGREE STRAIGHT DOWN FROM COOLER INLET · ALSO AN ATTACHMENTC152
280-6955 LINES GP-AIRS/N SDP1-405 · PROVIDES AN OVER THE FLYWHEEL HOUSING OEM CLEAN GAS INDUCTION CONNECTING POINTC152
280-6955 LINES GP-AIRS/N SDP406-UP · PROVIDES AN OVER THE FLYWHEEL HOUSING OEM CLEAN GAS INDUCTION CONNECTING POINTC152
283-0255 LINES GP-AIRS/N SDP1-537 · PROVIDES AN OVER THE FLYWHEEL HOUSING OEM CLEAN GAS INDUCTION CONNECTING POINTC154
283-0255 LINES GP-AIRS/N SDP538-1099 · PROVIDES AN OVER THE FLYWHEEL HOUSING OEM CLEAN GAS INDUCTION CONNECTING POINTC154
285-0207 LINES GP-CLEAN GAS INDUCTION -COOLER INLETPROVIDES A CLEAN GAS INDUCTION CONNECTING POINT ORIENTED 90-DEGREES DOWN FROM THE CLEAN GAS INDUCTION COOLER INLET · FOR USE WITH VERTICAL VENTURIC154
280-6957 MOUNTING GP-SENSORPROVIDES AN OEM CLEAN GAS INDUCTION CONNECTING POINT 90-DEGREES DOWN FROM CLEAN GAS INDUCTION COOLER INLET · FOR USE WITH ENGINES WITH A VERTICAL VENTURIC152
224-5396 LINES GP-AIR -LOW MOUNTPROVIDES INNER STAGE DUCTING FOR LOW-MOUNT TURBOCHARGER · ALSO AN ATTACHMENTC134×2
224-5397 LINES GP-AIR -HIGH MOUNTPROVIDES INNER STAGE DUCTING FOR THE HIGH-MOUNT TURBOCHARGER · ALSO AN ATTACHMENTC134×2